 1332 CO2, GENERATOR INSTALLATION INSTRUCTIONS

NOTE: Proper ventilation must be supplied when using this heater. Approximately one (1) air change per hour.

 Hang unit from ceiling to the desired height by using chain. (Not supplied with unit.)

 Run gas line to the inlet of the unitrol valve. Gas pressure at the inlet should be 5" to 7" water column (3 ounces) on natural gas and 11" water column (6 ounces) on LP gas while the burner is in operation.

 Supply a 24 volt electrical source to the unitrol valve. See form 292 for typical wiring diagrams. The 24 volt transformer, room thermostat and time switch can be purchased as optional equipment from the Johnson Gas Appliance Company. As many as three generators can be operated from one of these control set ups.

 See form 294 for lighting instructions. See charts below for proper burner settings.

 Check size of hot house area, adjust manual gas valve to obtain proper pressure gauge reading. 

LP Gas (Use H.D. 5 Propane)

Natural Gas

Pressure
Gauge Reading
Inches W.C.

Gas Input
BTUH/hr.

Hot House Area in Square ft.

Pressure Gauge
Reading Inches
W.C.

Gas Input
BTUH/hr.

Hot House Area in Square Ft.

11

60,000

4,800

5

63,800

4,250

9

54,500

4,320

4

57,500

3,850

7

47,800

3,820

3

50,200

3,350

5

40,400

3,220

2

40,400

2,700

3

31,300

2,500

1

28,475

1,900