Form 295
1332
CO2,
GENERATOR INSTALLATION INSTRUCTIONS
 |
NOTE:
Proper
ventilation must be supplied when using this heater. Approximately one (1)
air change per hour.
Hang unit from ceiling to the desired
height by using chain. (Not supplied with unit.)
Run gas line to the inlet of the unitrol
valve. Gas pressure at the inlet should be 5" to 7" water column (3 ounces)
on natural gas and 11" water column (6 ounces) on LP gas while the burner is
in operation.
Supply a 24 volt electrical source to the
unitrol valve. See form 292 for typical wiring diagrams. The 24 volt
transformer, room thermostat and time switch can be purchased as optional
equipment from the Johnson
Gas Appliance Company. As many as three generators can be operated from one
of these control set ups.
|
See form 294 for
lighting instructions. See charts below for proper burner settings.
Check size of hot
house area, adjust manual gas valve to obtain proper pressure gauge reading.
|
LP Gas (Use H.D.
5 Propane) |
Natural Gas |
|
Pressure
Gauge Reading
Inches W.C. |
Gas Input
BTUH/hr. |
Hot House Area in Square ft. |
Pressure Gauge
Reading Inches
W.C. |
Gas Input
BTUH/hr. |
Hot House Area in Square Ft. |
|
11 |
60,000 |
4,800 |
5 |
63,800 |
4,250 |
|
9 |
54,500 |
4,320 |
4 |
57,500 |
3,850 |
|
7 |
47,800 |
3,820 |
3 |
50,200 |
3,350 |
|
5 |
40,400 |
3,220 |
2 |
40,400 |
2,700 |
|
3 |
31,300 |
2,500 |
1 |
28,475 |
1,900 |
To go back to the Navigation page click on the link below.
CO2 GENERATOR
MANUAL HOME PAGE
|