Tree Planters and Co2 Generators
   Home | Links and More Info | FAQ's | Product Selection Oriface Replacement

Form 314

NO. 1332 CO2 GENERATOR ORIFICE REPLACEMENT INSTRUCTIONS

 TO REPLACE PILOT ORIFICE IN #1332 CO2 GENERATOR

 1.  Remove thermocouple by loosening thermocouple holding nut to give ready access to pilot line.

2.   Loosen pilot line compression fitting.

3.   Remove screws holding pilot and remove pilot from unit.

4.   Remove pilot orifice and replace with proper orifice.

5.    Replace pilot, pilot line, and thermocouple.

       Be sure to snug up all connections to prevent possibility of gas leaks.

 TO REPLACE MAIN BURNER ORIFICE

1. Remove present main burner orifice as shown above.

2. Screw in proper orifice.

ORIFICE SIZES

 

LP GAS

NATURAL GAS

Main Burner

#45 Drill

#27 Drill

Pilot

.013

.023

  To go back to the Navigation page click on the link below.
CO2 GENERATOR MANUAL HOME PAGE 

MANUFACTURED BY:
JOHNSON GAS APPLIANCE COMPANY
CEDAR RAPIDS, IOWA 52405

EXPORTED BY:
AEON INTERNATIONAL CORP.
MARION, IOWA 52302